Products
- Waste Management[1]
- Daily Chemicals[1]
- Chemical Auxiliary Agent[3]
- Food Additives[9]
- Other Chemicals[10]
- Carbonate[2]
- Alkali[2]
- Nitrate[5]
- Chloride[1]
- Dyestuffs[1]
- Nitrogen Fertilizer[1]
- HDPE[7]
- Paint & Coating[3]
- PP[2]
- PVC[1]
- Aluminum Billets[2]
- Other Billets[5]
- Zinc[1]
- Ester & Derivatives[7]
- Other Metals & Metal Products[1]
- Inorganic Acids[10]
- Other Inorganic Chemicals[4]
- LDPE[2]
- Polymer[6]
- Other Plastic Raw Materials[5]
- Sulphate[4]
- Organic Acid[5]
- Organic Intermediate[6]
- Oxide[7]
- Alcohol & Hydroxybenzene & Ether[9]
- Other Inorganic Salts[2]
- Organic Salt[2]
- Other Organic Chemical[1]
- Other Ingots[1]
- Pigment[1]
Contact Us
- Contact Person : Ms. Phoebe Miss
- Company Name : Dezhou Decheng District Xingtai Chemicals Material Distribution Dept.
- Tel : 86-0534-2683889
- Fax : 0534-2691097
- Address : Shandong,jinan,China's shandong jinan LiChengOu jinan LiChengOu good garden chemical market A2-19
- Country/Region : China
- Zip : 250100
PVC Granule
Product Detailed
Related Categories:PVC
1.PVC compound for wire and cable
2.Good plasticization
3.Uniform color
4.No significant impurities
CONTACT :KIONA
1.Directory & Use
NO. | TYPE | PRODUCT NAME | The maximum allowable operating temperature of the conductive core | APPLICATION |
1 | J-70 | 70°C PVC insulting compound | 70°C | Used for instrument and communication cables which working voltage less than 0.6/1KV |
2 | JR-70 | 70°C flexible PVC insulting compound | 70°C | Used for flexible cable which working voltage less than 450/750V |
3 | JK-70 | 70°C overhead PVC insulating compound | 70°C | Used for overhead cable which working voltage less than 1KV |
4 | JZ-70 | 70°C flame retardant PVC insulating compound | 70°C | Used for instrument and communication cables which working voltage less than 0.6/1KV,requiring flame retardant |
5 | JGD-70 | 70°C high electrical properties PVC insulating compound | 70°C | Used for power cables which working voltage less than 3.6/6KV |
6 | JRZ-70 | 70°C flexible flame retardant PVC insulating compound | 70°C | Used for flexible cable which working voltage less than 450/750V,requiring flame retardant |
7 | H-70 | 70°C PVC jacket compound | 70°C | Used for wire and cables which working voltage less than 450/750V |
80°C | Used for power cables which working voltage less than 26/35KV | |||
8 | HR-70 | 70°C flexible PVC jacket compound | 70°C | Used for flexible wires and cables whcih working voltage less than 450/750V |
9 | HRZ-70 | 70°C flexible flame retardant PVC jacket compound | 70°C | Used for wires and cables which working voltage less than 450/750V,requiring flame retardant |
10 | HZ-70 | 70°C flame retardant PVC jacket compound | 70°C | Used for wires and cables which working voltage less than 450/750V,requiring flame retardant |
80°C | Used for power cables which working voltage less than 26/35KV,requiring flame retardant | |||
11 | J-90 | 90°C PVC insulating compound | 90°C | Used for heat resistant wires and cables which working voltage less than 450/750V |
12 | JZ-90 | 90°C flame retardant PVC insulating compound | 90°C | Used for heat resistant wires and cables which working voltage less than 450/750V,requiring flame retardant |
13 | HI-90 | I type 90°C PVC jacket compound | 90°C | Used for power cables and other similar cables which working voltage less than 35KV |
14 | HII-90 | II type 90°C PVC jacket compound | 90°C | Used for wires and cables which working voltage less than 450/750V |
15 | HZ-90 | 90°C flame retardant PVC jacket compound | 90°C | Used for power cables and other similar cables which working voltage less than 35KV,requiring flame retardant |
16 | GD-HZ-90 | High performance 90°C flame retardant PVC jacket compound | 90°C | 110KV & 220KV high voltage XLPE which requiring flame retardant |
17 | H-105 | 105°C PVC jacket compound | 105°C | Used for heat resistant wires and cables which working voltage less than 450/750V |
18 | HZ-105 | 105°C flame retardant PVC jacket compound | 105°C | Used for heat resistant wires and cables which working voltage less than 450/750V,requiring flame retardant |
19 | J-105 | 105°C PVC insulating compound | 105°C | Used for heat resistant wires and cables which working voltage less than 450/750V |
20 | JZ-105 | 105°C flame retardant PVC insualting compound | 105°C | Used for heat resistant wire and cables which working voltage less than 450/750V,requiring flame retardant |
2.Performance indicator
NO. | INDICATOR | UNIT | J-70 | JR-70 | JK-70 | JZ-70 | JGD-70 | JRZ-70 | H-70 | HR-70 | HZ-70 | HRZ-70 | J-90 | JZ-90 | HI-90 | HII-90 | HZ-90 | GD-HZ-90 | H-105 | HZ-105 | J-105 | JZ-105 | |
1 | Tensile strength ≥ | MPa | 15 | 15 | 15 | 15 | 16 | 15 | 15 | 12.5 | 15 | 12.5 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | |
2 | Tensile strain at break ≥ | % | 150 | 180 | 180 | 150 | 150 | 180 | 180 | 200 | 180 | 200 | 150 | 150 | 180 | 180 | 180 | 180 | 180 | 180 | 150 | 150 | |
3 | Thermal deformation ≤ | % | 40 | 50 | 50 | 40 | 30 | 50 | 50 | 65 | 50 | 65 | 30 | 30 | 40 | 40 | 40 | 40 | 50 | 50 | 30 | 30 | |
4 | Impact brittleness temperature | °C | -15 | -20 | -40 | -15 | -15 | -20 | -25 | -30 | -25 | -30 | -15 | -15 | -20 | -20 | -20 | -20 | -20 | -20 | -15 | -15 | |
5 | Thermal stable time at 200°C | min | 60 | 60 | 60 | 60 | 100 | 60 | 50 | 60 | 50 | 60 | 180 | 180 | 80 | 180 | 80 | 80 | 80 | 80 | 80 | 80 | |
6 | Volume resistance rate at 20°C ≥ | Ω.m | 1.0x1012 | 1.0x1011 | 1.0x1011 | 1.0x1012 | 1.0x1012 | 1.0x1011 | 1.0x108 | 1.0x108 | 1.0x108 | 1.0x108 | 1.0x1012 | 1.0x1012 | 1.0x109 | 1.0x109 | 1.0x109 | 1.0x1011 | 1.0x109 | 1.0x109 | 1.0x1011 | 1.0x1012 | |
7 | Volume resistance rate at operation temperature | Test temperature | °C | 70±1 | 70±1 | 70±1 | 70±1 | 70±1 | 70±1 | —— | —— | —— | —— | 95±1 | 95±1 | —— | —— | —— | 90±1 | —— | —— | 95±1 | 95±1 |
Volume resistivity ≥ | Ω.m | 1.0x109 | 1.0x108 | 1.0x108 | 1.0x109 | 5.0x109 | 1.0x108 | —— | —— | —— | —— | 5.0x108 | 5.0x108 | —— | —— | —— | 1.0x109 | —— | —— | 5.0x108 | 5.0x108 | ||
8 | Dielectric strength ≥ | MV/m | 20 | 20 | 20 | 20 | 25 | 20 | 18 | 18 | 18 | 18 | 20 | 20 | 18 | 18 | 18 | 20 | 18 | 18 | 20 | 20 | |
9 | Dielectric loss factor | % | —— | —— | —— | —— | 0.1 | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | |
10 | Properties after thermal aging | Test temperature | °C | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 135±2 | 135±2 | 100±2 | 135±2 | 100±2 | 100±2 | 135±2 | 135±2 | 135±2 | 135±2 |
Test time | h | 168 | 168 | 168 | 168 | 168 | 168 | 168 | 168 | 168 | 168 | 240 | 240 | 240 | 240 | 240 | 240 | 168 | 168 | 168 | 168 | ||
Tensile strength after aging ≤ | MPa | 15 | 15 | 15 | 15 | 16 | 15 | 15 | 12.5 | 15 | 12.5 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | ||
The maximum change of tensile strength | % | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ||
Tensile strain after aging ≥ | % | 150 | 180 | 180 | 150 | 150 | 180 | 180 | 200 | 180 | 200 | 150 | 150 | 180 | 180 | 180 | 180 | 180 | 180 | 150 | 150 | ||
The maximum change of tensile strain | % | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ±20 | ||
11 | Quality loss after thermal aging | Test temperature | °C | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 100±2 | 115±2 | 115±2 | 100±2 | 115±2 | 100±2 | 100±2 | 135±2 | 135±2 | 135±2 | 135±2 |
Test time | h | 168 | 168 | 168 | 168 | 168 | 168 | 168 | 168 | 168 | 168 | 240 | 240 | 240 | 240 | 240 | 240 | 168 | 168 | 168 | 168 | ||
Quality loss | g/m2 | 20 | 20 | 20 | 20 | 20 | 20 | 23 | 25 | 23 | 25 | 20 | 20 | 15 | 20 | 15 | 15 | 23 | 23 | 20 | 20 | ||
12 | Oxygen index ≥ | % | —— | —— | —— | 30 | —— | 30 | —— | —— | 30 | 30 | —— | 30 | —— | —— | 30 | 30 | —— | 30 | —— | 30 | |
13 | Atificial weathering | 0h-1008h rensile strength | % | —— | —— | ±30 | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— |
0h-1008h strain at break | % | —— | —— | ±30 | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | ||
504h-1008h tensile strength | % | —— | —— | ±15 | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | ||
504h-1008h tensile strain | % | —— | —— | ±15 | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— | —— |
PVC Granule